Ul building materials directory 41.
Csdma recommended dimensional standards for commercial steel doors and frames.
Weight or force shall be 2.
The csdma s recommended dimensional standards for commercial steel doors and frames.
Ashrae standard 90 1 energy standard for buildings except.
Sdi 111 2009 recommended selection and usage guide for standard steel doors frames and accessories table of contents.
Include 1 2 5 only if doors and frames are fabricated from stainless steel.
Info csdma ca the recommended dimensional standards for commercial steel doors and frames is available for download as a pdf file.
2 height heights of openings shall be measured from the finished floor exclusive of floor coverings to the head rabbet of the frame.
1 4 references spec note.
Recommended dimensional standards for commercial steel doors and frames these publications are available by request on line at.
American society of heating refrigerating and air conditioning engineers.
Exclude 1 2 12 if frame louvers or vents are supplied under this section.
All values which do not carry specific tolerances or are not marked maximum or minimum shall have the following tolerances.
This guide is intended to address dimensional standards for steel doors and frames in commercial industrial and institutional construction.
Stainless steel doors frames 08 11 19 csdma 2006 08130 1 width widths of openings shall be measured from inside to inside of frame jamb rabbets.
The publications listed in section 1 4 form part of this specification to the extent referenced.
Sound retardant steel doors frames 08 34 73 csdma 2006 08380 3 holes 12 7 mm 0 5 diameter and larger shall be facto ry prepared except mounting and through bolt holes which are by others on site at time of hardware installation.
The publications are referenced in the text by basic designation only.
Referred to as frame rabbet width or nominal door width.
The csdma is a voluntary non profit organization representing full line manufacturers of commercial steel door and frame products.
Manufacturers standard and galvanized sheet gages 40.
Exclude 1 2 11 and 1 2 13 if door louvers or vents are supplied under this section.
Ansi bhma a156 115 hardware preparation in steel doors or steel frames.
Fleming fire labeling specifications 39.
Linear dimensions shall be 1 16 in.
111 a recommended standard steel door frame details 111 b recommended standard details for dutch doors 111 c recommended louver details for standard steel doors 111 d recommended door frame and hardware schedule for standard steel doors and frames.