The 2 3 side wall direct vent kit is for use with high efficient condensing furnaces.
Direct vent furnace sidewall vent kit.
For use with direct vent furnace side wall vent kit function this vent kit is only to be used for venting category iv condensing furnaces do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces do not use for roof top venting how can we improve our technical specifications.
This kit is not intended for use with single pipe indirect vent installations.
Do not use for roof top venting use this kit for side wall venting only.
Combustion products are discharged outdoors through the wall vent.
Refer to the furnace installation instructions for intake vent pipe sizing information.
This vent kit is to be used with 2 vent systems.
Vent kit is not for use with single pipe indirect vent installations.
This is an alternative to the standard two pipe intake vent shown in the basic furnace installation instructions.
So even if your furnace were to be approved for side wall venting b vent is not the proper type of vent pipe to use.
This eliminates the expense of a vent.
Direct vent counterflow the forced air circulation comfort heating system uses only outside air for combustion as the burners are completely sealed within the combustion chamber.
A sidewall power venter can be installed.
Air necessary for combustion is drawn into the.
Cvent 3 is for use with 3 in.
Warning do not use the concentric vent kit for anything other than a category iv furnace.
For clean comfortable heat when and where you want it the gas flame is completely sealed inside away from all contact with room air.
The vent kit must terminate outside the structure and can be installed with the intake and exhaust pipes located side by side or with one pipe above the other.
Direct vent furnace side wall vent kit 0170k00001s.
Next b vent is for negative pressure draft systems only.
The vent kit must terminate outside the structure and may be installed with the intake and exhaust pipes located side by side or with one pipe above the other.
It provides an alternative to the traditional two pipes out the wall option.
All vent caps include a built in bird guard.
Do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces.
The york etc used a stainless flex pipe and not b vent.
The space saving direct vent furnace design mounts to an exterior wall and the adjustable vent assembly adjusts to fit walls from 4 1 2 in.
It also has a more attractive appearance on the outside of the building.
I0 635a september 2013 warning this vent kit is only to be used for venting category iv condensing furnaces.